带 EtherNet/IP接口激光测距传感器
的详细介绍带 EtherNet/IP接口激光测距传感器 LDM42EI
带 EtherNet/IP接口激光测距传感器 LDM42EI
带 EtherNet/IP接口激光测距传感器 LDM42EI
The LDM41EI is an optoelectronic distance measuring device for industrial applications with EtherNet/IP interface.
It works contact-free on the principle of comparative phase measurement (amplitude modulation) and facilitates precisely accurate measurement of distances.
Both, the LDM41EI and the LDM42EI distinguish themselves through high precision as well as high independence from the surface of the measuring object. The red, well visible laser beam allows for easy alignment. The LDM42EI has been further developed for fast distance measurements on white surfaces.
Through the integrated EtherNet/IP interface it is possible to read in data of several devices into a control easily.
Applications
0.2 m ... 30 m on almost all natural surfaces, over 100 m achievable depending on the degree of reflection of surfaces 0.1 mm, freely scalable 0.5 mm 0.24 s ... 6 s adjustable or automatically in mode DT 10 V ... 30 V direct currents RS232, max. Baud rate 38400, ASCII, setting of measuring functions, scaling, measuring time via commands, display of measured values, internal temperature of the device and error code Programmable switching threshold and hysteresis, "high side" switch, maximum load 0.5 A Aluminum anodized 4 drill holes for M6 screws, 100 mm x 85 mm
Measuring range1 Measuring uncertainty2 ±2 mm under defined measuring conditions3
±3 mm (+15°C ... +30°C)
±5 mm (-10 °C ... +50 °C) Resolution Reproducibility4 Measuring time
0.1 s in mode DW on white surface
20 ms in mode DX on white surface (only LDM42EI) Laser class Laser class 2 acc. to DIN EN 60825-1:2001-11 Laser divergence5 0.6 mrad Operating temperature -10 °C ... +50 °C Storage temperature -40 °C ... +70 °C Supply voltage Power consumption Ca. 4 W Serial interface Fieldbus6 Profinet Switching output Housing material Size (LxBxH) 187 mm x 96 mm x 50 mm Weight 850 g Protection class IP 65 Shock resistance 10 g / 6 ms (DIN ISO 9022-3-31-01-1) MTBF 30,000 hours at 25 °C Mounting
Annotations to technical data:
1 Dependent on target reflectance, influence of extraneous light and atmospheric conditions 2 Statistical spread of 95 % 3 Measurement on planar, vertical white surface at standstill or in continuous movement, + 15 °C to +30 °C 4 Dependent on target reflectance, influence of extraneous light and atmospheric conditions 5 At a distance of 10 m the beam diameter is 6 mm, at 100 m it is 6 cm
所有评论仅代表网友意见,与本站立场无关。